Ready to Run Sequencing
Your Industry, Our Focus
Use our ABI 3730 XL platform when you need reliable sequencing of your pre-cycled sequencing samples. We are providing the result within 1 day just after receiving samples.
Ready-to-Run sequencing includes
- Electrophoresis with ABI3730xl DNA Analyzer.
- Base calling with Sequencing Analysis 5.2
- Storage of chromatograms into Seq Lab database.
Sample submission
Applied Biosystems recommends following amounts of templates for sequencing:
Template Length |
Quantity |
Volume (µL) |
PCR 100-200 bp |
3-5 ng |
20 |
PCR 200-500 bp |
3-10 ng |
20 |
PCR 500-1000 bp |
5-20 ng |
20 |
PCR 1000-2000 bp |
10-40 ng |
20 |
PCR >2000 bp |
20-50 ng |
20 |
ssDNA |
20-50 ng |
20 |
Plasmid DNA |
150-300 ng |
20 |
We are accepting the samples in tubes or culture plates . We have 3 different services under this service:
- Ready to run tube: Cleaned, cycle Sequencing products on tube format
- Ready to run 96 well plate: Cleaned, cycle Sequencing products on 96 well plate format
Provide all samples name according to the plate format. If you need sizing information, please provide the details of labeling and product size.
Deliverables:
Raw sequencing files.
Ready to run tube
Use our ABI 3730 XL platform when all you need is reliable sequencing of your pre-cycled sequencing samples. We are providing the result within 1 day just after receiving samples.
Ready-to-Run sequencing includes
- Electrophoresis with ABI3730xl DNA Analyzer.
- Base calling with Sequencing Analysis 5.2
- Storage of chromatograms into SeqLab database.
Sample submission
Applied Biosystems recommends following amounts of templates for sequencing:
Template Length |
Quantity |
Volume(µL) |
PCR 100-200 bp |
3-5 ng |
20 |
PCR 200-500 bp |
3-10 ng |
20 |
PCR 500-1000 bp |
5-20 ng |
20 |
PCR 1000-2000 bp |
10-40 ng |
20 |
PCR >2000 bp |
20-50 ng |
20 |
ssDNA |
20-50 ng |
20 |
Plasmid DNA |
150-300 ng |
20 |
Ready to run 96well plate
Use our ABI 3730 XL platform when you need reliable sequencing of your pre-cycled sequencing samples. We are providing the results within 1 day just after receiving samples.
Ready-to-Run sequencing includes
- Electrophoresis with ABI3730xl DNA Analyzer.
- Base calling with Sequencing Analysis 5.2
- Storage of chromatograms into SeqLab database.
Sample submission
Applied Biosystems recommend following amounts of templates for sequencing:
Template Length |
Quantity |
Volume(µL) |
PCR 100-200 bp |
3-5 ng |
20 |
PCR 200-500 bp |
3-10 ng |
20 |
PCR 500-1000 bp |
5-20 ng |
20 |
PCR 1000-2000 bp |
10-40 ng |
20 |
PCR >2000 bp |
20-50 ng |
20 |
ssDNA |
20-50 ng |
20 |
Plasmid DNA |
150-300 ng |
20 |